Fuel Level Sensor - Malaguti CENTRO SO 4T Service Manual

Frame and running gear
Table of Contents

Advertisement

50 cc - 4 T

FUEL LEVEL SENSOR

• During operations, screw the tank cap on the union (A),
to avoid that any foreign matter falls inside.
• Remove the adhesive tape (B), release the sheaths
(F) and disconnect the inside connector.
• V4.
• Remove the fuel level sensor (G).
NOTE - When reassembling, insert the floater (C) so
that the base remains as it was originally. It is
advisable to mark the correct position before
removal. Check the condition of the gaskets
(D) and replace them if necessary.
FUEL TANK
Do not smoke or
use open flames,
while operating on the fuel
tank.
• During the operation, screw
the tank cap, to avoid that
any foreign matter falls
inside.
• V4.
V
4
5 ± 10%
F. 65
A
G
F. 63
F
V
4
V
4
31
07/08
V
4
B
• Remove the cover (1).
• Undo the clamp (B) and remove the vacuum valve (C).
Remove the tank and place it far from heat sources and sparks and/
or open flames.
1
F. 66
F. 66/a
V
G
4
C
D
F. 64
B
C

Hide quick links: