Injection Precautions - Gilera GP 800 i.e. Service Station Manual

Table of Contents

Advertisement

Injection
The EMS control unit power supply is further con-
trolled by the emergency switch, side stand switch
and the stop buttons; that is to provide further
safety for the scooter.
Precautions
1. Before fixing any part of the injection system, check to see if there are any registered faults. Do not
disconnect the battery before checking for faults.
2. The fuel supply system is pressurised at 300 kPa (3 BAR). Before disconnecting the quick coupler
of a pipe in the fuel supply system, check that there are no naked flames, and do not smoke. Act with
caution to prevent spraying in the eyes.
3. When fixing electric components, operate with battery connected only when actually required.
4. When functional checks are performed, check that the battery voltage is over 12V.
5. Before trying to start the vehicle, check to make sure there is at least two litres of fuel in the tank.
Failure to respect this norm will damage the fuel pump.
6. If the scooter is expected to remain unused for a long time, refill the tank up to a little over half the
level. This will ensure the pump will be covered by fuel.
7. When washing the vehicle, be careful with the electric components and wiring.
8. When an ignition problem is detected, start the checks from the battery and the injection system
connections.
9. Before disconnecting the EMS control unit connector, perform the following operations in the order
shown:
- Set the switch to «OFF»
- Disconnect the battery
Failure to respect this norm may damage the control unit.
10. Do not invert the polarity when fitting the battery.
11. In order to prevent damages, disconnect and reconnect the EMS connectors only if actually required.
Before reconnecting, check that the connectors are dry.
12. When carrying out electric inspections, do not force the tester probes into the connectors. Do not
take measurements not specifically foreseen by the manual.
13. At the end of every check performed with the diagnostic tester, protect the system connector with
its cap. Failure to observe this norm may damage the EMS control unit.
14. Before reconnecting the quick couplers of the power supply system, check that the terminals are
perfectly clean.
INJEC - 4
GP 800 i.e.