Injection Warning Light Circuit; Yes Go To 6 No Go To 7 - Gilera Nexus 500 Workshop Manual

Hide thumbs Also See for Nexus 500:
Table of Contents

Advertisement

Nexus 500
5 - Check the following conditions:
PIN 1 diagnostic socket - PIN 10 control unit =
continuity
PIN 2 diagnostic socket - PIN 23 control unit =
continuity with earth
PIN 3 diagnostic socket - PIN 9 control unit = con-
tinuity
10 - 23 = insulation (>1 MΩ)
9 - 23 = insulation (>1 MΩ)

YES go to 6 NO go to 7

6 - The circuit is in good working order. Check the control unit.
7 - Fix the interruption or short-circuit.

Injection warning light circuit

1
2
3
1
CIRCUIT LAYOUT
Specification
Instrument panel
Fuse
Electronic control unit
Specification
TERMINAL: 15 - 23
Desc./Quantity
[
]
P
Desc./Quantity
CONDITIONS: DURING THE CHECK
- Switch set to "ON"
Injection
7.5 A
INJEC - 209