Sealed Battery; Instructions For Battery Refresh After Open Circuit Storage - Gilera GP 800 i.e. Service Station Manual

Table of Contents

Advertisement

GP 800 i.e.
5
6
7
8
9
10
11
12

Sealed battery

Sealed battery start-up operations
If the vehicle is provided with a sealed battery, the only maintenance required is the check of its charge
and recharging, if necessary.
These operations should be carried out before delivering the vehicle, and on a six-month basis while
the vehicle is stored in open circuit.
Besides upon pre-delivery it is therefore necessary to check the battery charge and recharge it, if re-
quired, before storing the vehicle and afterwards every six months.

INSTRUCTIONS FOR BATTERY REFRESH AFTER OPEN CIRCUIT STORAGE

1) Voltage check
Before installing the battery on the vehicle, check the open circuit voltage with a regular tester.
- If voltage exceeds 12.60 V, the battery can be installed without any renewal recharge.
- If voltage is below 12.60 V, a renewal recharge is required as explained in 2).
2) Constant voltage battery charge mode
- Constant voltage charge equal to 14.40 ÷ 14.70V
-Initial charge voltage equal to 0.3 ÷ 0.5 for Nominal capacity
- Charge time:
Specification
Fuse No. 5
Fuse No. 6
Fuse No. 7
Fuse No. 8
Fuse No. 9
Fuse No. 10
Fuse No. 11
Fuse No. 12
Desc./Quantity
Protected circuits: Turn indicator control
device.
Live: Fuses No. 10-11-12.
Capacity: 7.5 A
Protected circuits: Instrument panel.
Capacity: 5A
Protected circuits: ECU, decoder.
Capacity: 15A
Protected circuits:Low-beam light relay,
high-beam light (via relay), low-beam light
(via relay).
Capacity: 10 A
Protected circuits (live): Wiring for acces-
sories, horn, stop light, high-beam light relay.
Capacity: 7.5 A
Protected circuits (live): Injection load re-
lay, electrical fan relay, ECU, decoder.
Capacity: 7.5 A
Protected circuits (live): Saddle opening
receiver, turn indicator control device, tail
lights, instrument panel.
Capacity: 7.5 A
Protected circuits (live): Wiring for GPS,
pre-installation for antitheft device, parking
brake.
Capacity: 5A
Protected circuits (live): Windshield relay,
engine for windshield (via relay).
Electrical system
ELE SYS - 47

Hide quick links:

Advertisement

Table of Contents
loading