Gilera GP 800 i.e. Service Station Manual page 11

Table of Contents

Advertisement

GP 800 i.e.
Specification
OIL MINIMUM PRESSURE INDICATOR LIGHT SWITCH
Specification
Calibration
Specification
Diameter
* Tightening torque 5÷7 N·m
Specification
Diameter
Specification
Device
Specification
Cooling system capacity
Prescribed fluid
Sealing pressure
Specification
Starts opening
Specification
Electric ventilation starts at
Electric ventilation stops at
Specification
Control
Specification
OIL FILTER
Type
HEAD LUBRICATION CONTROL JET
PISTON COOLING NOZZLE
CRANKCASE VENTILATION CHECK
TECHNICAL SPECIFICATIONS
THERMOSTAT
Type
ELECTRIC VENTILATION
Type
WATER PUMP
Type
RADIATOR
Type
Desc./Quantity
Paper with pressure relief and anti-drain back by-
pass valves
Desc./Quantity
0.3 - 0.6 bar
Desc./Quantity
1 ± 0.05 mm *
Desc./Quantity
Ø 1 ± 0.05 mm
Desc./Quantity
metal reed valve and decantation chamber
Desc./Quantity
2.4 l
AGIP PERMANENT SPEZIAL
Cap calibrated at 0.9 bar
Desc./Quantity
Wax-type, with deviator
85±2°C
Desc./Quantity
With piston
105°C
100°C
Desc./Quantity
Centrifugal
Gear on oil delivery pump
Desc./Quantity
Aluminium, with horizontal circulation
Characteristics
CHAR - 5