Pinion Unit - Gilera GP 800 i.e. Service Station Manual

Table of Contents

Advertisement

Maintenance
Spray lubricating grease for chains and gears

PINION UNIT

The pinion unit oil should be checked and changed
as indicated in the scheduled maintenance table.
The oil level should never be below the "MAX" ref-
erence mark indicated in the figure. Otherwise:
- Undo screw «D».
- Restore the level by adding recommended oil
with a syringe taking care not to exceed the
"MAX" reference mark indicated in the figure.
WARNING
DO NOT EXCEED THE "MAX" LEVEL WHEN
TOPPING UP.
Recommended products
AGIP ROTRA MP 80W-90 Transmission oil
SAE 80W-90, API GL-5
- Tighten the drain screw to the prescribed torque.
Locking torques (N*m)
Pinion unit oil filling screw 13 ÷ 15
MAIN - 18
GP 800 i.e.

Hide quick links:

Advertisement

Table of Contents
loading