Timer Display; Dip Switch Display - Milnor MWR09E5 Series General Operating And Troubleshooting

Washer-extractors with the e-p onetouch controller
Hide thumbs Also See for MWR09E5 Series:
Table of Contents

Advertisement

Chart 5: Overview of Run Mode Diagnostics
A1:
Lock off/tag off power.
A2:
Connect display harness.
A3:
Restore machine power.
A4:
Start any formula.
A5:
View timer display.
A6:
View DIP switch display.
A7:
View inputs.
A8:
View outputs.
View analog-to-digital
A9:
channels.
A10:
Return to timer display.
Go to A4

Timer Display

4.2.2.2.
1.
in the power-up safety delay and the In Progress light flashes.When you start a formula, the
Start
—When power is supplied to the machine, the display shows the time remaining
Chapter 4. Testing and Troubleshooting
CAUTION 13 : Electrocution and Electrical Burn Hazards—Contact
with electric power can kill or seriously injure you. Electric power is
present inside the cabinetry unless the main machine power disconnect is
off.
Section 4.2.2.1 "Connecting the Display" details how to connect the display
harness to the machine controller.
The power-up safety delay begins counting down when power is restored to the
machine. When the delay time expires, the display changes to indicate that the
controller is ready to run a formula.
Press a formula button to start the desired formula.
The timer display appears when the formula starts. The timer display is
described in Section 4.2.2.2.1. When bath level (and optionally, temperature) is
achieved, the timer starts.
>
Press
from the timer display to advance to the DIP switch display. Details of
the DIP switch display are described in Section 4.2.2.2.2.
>
Press
when the DIP switch display is present and a formula is running to
advance to the inputs display. Details of the inputs display are described in
Section 4.2.2.2.3.
>
Press
when the inputs display is present and a formula is running to advance
to the outputs display. Details of the outputs display are described in Section
4.2.2.2.4.
>
Press
when the outputs display is present and a formula is running to
advance to the analog-to-digital channels display. This display is described in
Section 4.2.2.2.5.
>
Press
when the analog-to-digital channels display is present to return to the
timer display.
>
Press
to cycle through the displays again, or press
formula and return to the timer display.
z
to end the current
PELLERIN MILNOR CORPORATION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mwr18e4

Table of Contents