Chapter 4. Testing and Troubleshooting
display shows certain information about machine operation as it occurs.
Display or Action
Please Wait 99 Secs.
F:x EQ:xxx CE:xxx
Level Ax/Dx T-Stop
F:x—Selected formula, if any. The "x" this field is replaced by A, B, C, or D, when a formula is
running.
EQ:xxx—Elapsed quarters. This field shows how many quarter-minute (15-second) periods have
expired since the timer began running.
Note 10: Because the timer doesn't start running until the desired level is achieved, this field will not
change from 000 to 001 until 15 seconds after level is achieved.
CE:xxx—Current event. Each of the four available wash formulas is made up of a series of
events. These events are numbered upward continuously through all formulas, so formula A
contains events 0 through 9, formula B is events 10 through 23, etc. Tables with descriptions
of all events are in Section 4.4. "Event Timing for 08BT168BT Controller Boards".
Level Ax/Dx—Level achieved and desired. Low level is represented by "1," and high level is
represented by "2." Achieved level is the number after "A," and desired level is the number
after "D." For example, "A0/D2" indicates that level 2 is desired, but the actual level is still
below low level. "A2/D2" indicates that level 2 is desired and achieved.
T-xxxx—Timer status. "T-Run" indicates that the timer is running, while "T-Stop" indicates that
the timer is stopped. The timer is stopped while the machine is filling and when the timer stop
input is present.
DIP Switch Display
4.2.2.2.
2.
button once to view the on/off status of the eight positions of the DIP switch. On this display
only, "+" indicates that the switch position is off and "–" indicates that the switch position is on.
Display or Action
F:C EQ:026 CE:024
Level A1/D1 T-Run
87654321
-++-+-++
Inputs Display
4.2.2.2.
3.
button once to view the on/off status of the eight controller inputs.
PELLERIN MILNOR CORPORATION
Explanation
Typical power-up display immediately after applying power to
the machine. The In Progress light (
Typical display when the machine is ready to run, but before
starting a formula.
—From the timer display with a formula running, press the Formula C
Explanation
This is a typical timer display.
Scrolls from the timer display to the DIP switch display.
>
This example of the DIP switch display shows that positions 8,
5, and 3 are on, and the other positions are off. See Section 2.1.3
"Configuration Decisions for Machines with Controller
08BT168BT" for the application of each switch position.
—From the DIP switch display with a formula running, press the Formula C
) flashes during the delay.
\