Table 8: Controller 08BT168BT: Summary of Configuration Decisions
Switch
Number
1
2
3
4, 5
6
7
8

Position 1: Configure for hospitality?

2.1.3.1.
machine uses formulas designed for the hospitality industry or formulas designed for healthcare
facilities. Set this position on to choose from the available hospitality formula sets. Set this
switch off to choose from the healthcare formula sets. The available formulas in each set are
listed in Section 1.5. "Formulas in Milnor

Position 2: Use Bed and Bath Linen formulas?

2.1.3.2.
the formula set used. Set this switch positon on to configure the machine for bed and bath linen
formulas. Set this switch off to use the kitchen/dining and personal goods formulas. Formulas for
each configuration are listed in Section 1.5. "Formulas in Milnor
®
OneTouch
Controls".
An authorized technician can set the machine to diagnostic mode (see Section 2.1.3.7 "Position
8: Set machine to normal operating mode?") to allow manual operation for troubleshooting
(position 8 off and position 2 on).
CAUTION 10 : Entangle and Crush Hazards—Contact with moving components
normally isolated by guards, covers, and panels, can entangle and crush your limbs. These
components move automatically.
• Verify that switch position 2 is on before changing switch position 8 to allow
troubleshooting.
On/Off
Position
Off
Healthcare
On
Hospitality
Off
Kitchen/dining and personal goods
On
Bed and bath linens
Note: Always set switch 2 On before changing switch 8 to begin
troubleshooting.
Off
Split water for final rinse step
On
Cold water for final rinse step
Off, Off
Hot bath temperature is 150°F (65.5°C)
On, Off
Hot bath temperature is 160°F (71.1°C)
Off, On
Hot bath temperature is 170°F (76.7°C)
On, On
Hot bath temperature is 180°F (82.2°C)
Off
Split bath temperature is 120°F (48.9°C)
On
Split bath temperature is 140°F (60°C)
Off
Hold step timer until temperature is achieved.
On
Run step timer while heating to desired temperature.
Off
Machine in diagnostic/troubleshooting mode
Note: Verify that switch 2 is Off before changing switch 8 to begin
troubleshooting.
On
Machine in normal operating mode
®
Description
—Switch position 1 determines whether the
Washer-extractors with E-P OneTouch
—DIP switch position 2 determines
®
Washer-extractors with E-P
Chapter 2. Configuring
®
Controls".
PELLERIN MILNOR CORPORATION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mwr18e4

Table of Contents