Chapter 2. Configuring
Configuration Decisions for Machines with Controller
2.1.2.
08BT168AT

Position 1: Use Formula Set A?

2.1.2.1.
used. Set this switch position on to configure the machine for the four primary formulas (Set A),
which are designed primarily for bed and bath linen. Set this switch off to use the alternate set of
formulas (Set B, primarily for kitchen/dining and personal goods). The formulas are listed in
Section 1.5. "Formulas in Milnor

Position 2: Cold final rinse?

2.1.2.2.
water may be too cold to allow the proper activation of some chemicals. In these locations, turn
switch position 2 off to cause both water valves to open for all sour/softener steps.

Positions 3 through 6: not used

2.1.2.3.
these machine models comprising controller board 08BT168AT. These positions have no effect
on the operation of the machine.

Position 7: Normal operation?

2.1.2.4.
preparing and testing the board before installation. Set this switch position on before first
commissioning the machine, or before installing a replacement board. The machine will not
enter the diagnostics mode if this position is on.

Position 8: Normal operation?

2.1.2.5.
configured for normal operation or for diagnostics. With this position on, the machine operates
normally by running formulas. Verify that this switch position is on before first
commissioning the machine, or before installing a replacement board.
When switch position 8 is off, the machine is configured for diagnostics. In this configuration, an
optional display can be connected to the processor board to aid in diagnosing problems when a
qualified technician manually actuates individual outputs.
Configuration Decisions for Machines with Controller
2.1.3.
08BT168BT
Usually, each switch represents a configuration decision with two possible answers. The
decisions and the result of each answer are described below.
In most cases, the answer to the configure decision is either yes or no. To answer yes, set the
Tip:
corresponding DIP switch to the on position by sliding the switch handle to the ON position. To
answer no, set the switch toward the position number.
PELLERIN MILNOR CORPORATION
—DIP switch position 1 determines the formula set
®
Washer-extractors with E-P OneTouch
—In some locations the temperature of the incoming cold
—DIP switch positions 3, 4, 5, and 6 are not used in
—The Milnor factory sets switch position 7 off when
—Switch position 8 determines whether the machine is
®
Controls".