Displays In Run Mode - Milnor MWR09E5 Series General Operating And Troubleshooting

Washer-extractors with the e-p onetouch controller
Hide thumbs Also See for MWR09E5 Series:
Table of Contents

Advertisement

Chapter 4. Testing and Troubleshooting
Figure 9: Processor Boards
A.
DIP switch
B.
Output relays
C.
Snubbers
D.
Outputs connectors
E.
Analog-to-digital connector
F.
Power connector
G.
Inputs connector
H.
Communication connector
I.
Pull-down resistor for JTAG port
J.
JTAG connector
K.
Voltage regulator (5V)
.

Displays in Run Mode

4.2.2.2.
select from five display modes without changing the DIP switch settings: timer, DIP switches,
inputs, outputs, and analog-to-digital channels. The timer display shows certain general
information about the current formula, as explained in Section 4.2.2.2.1. The DIP switches
display shows the on/off status of each DIP switch position. The inputs display (Section
4.2.2.2.3) shows the on/off status of each of the eight inputs. The outputs display, described in
Section 4.2.2.2.4, shows the on/off status of the 16 outputs. The analog-to-digital channel display
is detailed in Section 4.2.2.2.5.
PELLERIN MILNOR CORPORATION
Illustration
Legend
—With the display connected and power to the machine, you can

Hide quick links: