Chapter 4. Testing and Troubleshooting
Table 11: E-P OneTouch Outputs
Display
Output
Letter
Number
a
K0
b
K1
c
K2
d
K3
e
K4
f
K5
g
K6
h
K7
i
K8
j
K9
k
K10
l
K11
m
K12
n
K13
o
K14
p
K15
Analog-to-Digital Channels Display
4.2.2.2.
5.
Notice 14 : Analog-to-digital information applies to machines with board 08BT168B_ only.
From the inputs display, press the Formula C button once to view the values of the two analog-to-
digital channels. The temperature probe is connected to channel 0, and channel 1 is not used.
PELLERIN MILNOR CORPORATION
Output Description
Enable Door Unlock button
Signal inverter for drain speed
Close drain
Open hot water valve
Open cold water valve
Signal inverter for clockwise wash
Signal inverter for counter-
clockwise wash
Signal inverter for extract speed
Turn on Last Rinse light
Turn on In Progress light
In Progress Slave (08BT168AB) or
External Heat (08BT168BB)
Door Lock
Flush chemical manifold
Inject soap
Inject bleach
Inject sour/softener
Connector and Pins
MTA5 pins 9 and 10
MTA5 pins 7 and 8
MTA5 pins 3 and 4
MTA5 pins 1 and 2
MTA4 pins 9 and 10
MTA4 pins 7 and 8
MTA4 pins 3 and 4
MTA4 pins 1 and 2
light illuminates when last
MTA7 pins 9 and 10
bath step begins; flashes to
signal error
light is on throughout
MTA7 pins 7 and 8
formula; flashes to signal
error
actuates when optional
MTA7 pins 3 and 4
external heat is desired
MTA7 pins 1 and 2
MTA6 pins 9 and 10
MTA6 pins 7 and 8
MTA6 pins 3 and 4
MTA6 pins 1 and 2