Testing Mwr_ Washer-Extractors (Document Bicept02); Testing Without The Display Kit - Milnor MWR09E5 Series General Operating And Troubleshooting

Washer-extractors with the e-p onetouch controller
Hide thumbs Also See for MWR09E5 Series:
Table of Contents

Advertisement

the Terminate button (
turn the door latch handle.
After correcting any error with the inverter itself, start the formula again.
BICEPT02 (Published) Book specs- Dates: 20060823 / 20060823 / 20060823 Lang: ENG01 Applic: CEP
4.2. Testing MWR_ Washer-extractors

Testing without the Display Kit

4.2.1.
Most functions of this machine can be tested with an accurate digital voltmeter if the schematic
diagrams are available and you have a thorough understanding of how the machine normally
operates.
The following rules will help you determine the current machine event. The events in each
formula are listed in Section 4.4. "Event Timing for 08BT168BT Controller Boards".
Chart 1: Operating Sequence Part 1
Formula starts
A1:
Enable In Progress light
A2:
Lock door
Go to Chart 2.
) to clear the error condition. Finally, hold the Door Unlock button (
z
— End of BICEUT03 —
Chapter 4. Testing and Troubleshooting
The selected formula starts immediately when the operator presses one of the
four formula selection buttons.
The In Progress light on the control panel illuminated when the machine is
operating.
The controller commands the door latch to lock, preventing opening the door
while water is in the cylinder.
'