Table 27: Events For Healthcare Set - Milnor MWR09E5 Series General Operating And Troubleshooting

Washer-extractors with the e-p onetouch controller
Hide thumbs Also See for MWR09E5 Series:
Table of Contents

Advertisement

Table 27: Events for Healthcare Set 2, Formula D
Current
Event
Event Type
103
Flush
104
Drain
105
Suds
106
Drain
107
Bleach
108
Drain
109
Rinse
110
Drain
111
Extract
112
Coast
113
Rinse
114
Drain
115
Extract
116
Coast
117
Sour/softener
118
Drain
119
Extract
120
Coast
BICEUF03 (Published) Book specs- Dates: 20060823 / 20060823 / 20060823 Lang: ENG01 Applic: CEP
4.4. Event Timing for 08BT168BT Controller Boards
The following tables list the events in each formula. This information is especially useful when
testing the machine with the display kit connected, as explained in Section 4.1. "Troubleshooting
Errors".
Hotel and Hospitality Software
4.4.1.
Formula Set 1
4.4.1.1.
Table 28: Events for Hotel and Hospitality Set 1, Formula A
Current Event
0
1
2
3
4
5
6
7
8
9
Attributes
Split water to high level
Hot water to low level
Hot water to low level
Hot water to high level
Split water to high level
Cold water to low level
— End of BICEUF02 —
Event Type
Suds
Split water to low level
Drain
Rinse
Split water to high level
Drain
Rinse
Cold water to high level
Drain
Sour/softener
Cold water to low level
Drain
Extract
Coast
Chapter 4. Testing and Troubleshooting
Start Time
(QQQ)
0
8
13
53
58
86
91
99
104
108
113
121
126
130
135
151
156
184
Attributes
Start Time (QQQ)
End Time
(QQQ)
8
13
53
58
86
91
99
104
108
113
121
126
130
135
151
156
184
189
End Time (QQQ)
0
32
32
37
37
45
45
50
50
58
58
63
63
79
79
84
84
112
112
117