Chapter 2. Configuring

Position 3: Use cold water for the final rinse?

2.1.3.3.
the incoming cold water may be too cold to allow the proper activation of some chemicals. Set
this switch position off to cause both water valves to open for all sour/softener steps.

Positions 4 and 5: Select desired hot bath temperature

2.1.3.4.
are used together to determine which of four available temperatures is desired when a hot bath is
commanded. Set these switch positions according to Table 9 for the desired temperature.
Table 9: Quick Reference for Hot Bath Temperature
Desired Hot Bath
Temperature
150°F (65.5°C)
160°F (71.1°C)
170°F (76.7°C)
180°F (82.2°C)
Position 6: Use 140°F (60°C) for split bath temperature?
2.1.3.5.
temperatures for a split bath are 140°F (60°C) and 120°F (48.9°C). Set this switch position on to
choose 140 (60) or off for 120 (48.9).

Position 7: Run bath timer while heating?

2.1.3.6.
step timer runs or stops while the machine is heating to the desired bath temperature. Set this
switch position on to run the timer while heating. This setting may increase productivity by
allowing the machine to continue operation even though the desired bath temperature has not
been achieved.
Set the switch off to stop the timer until the desired temperature is achieved. Use this setting to
ensure that the goods are processed for the full programmed time at the desired temperature.

Position 8: Set machine to normal operating mode?

2.1.3.7.
determines whether the machine is ready to operate normally by running formulas, or is set for
diagnostics. Set this switch position on to run the machine normally. A qualified technician can
set this switch position off for manual output testing and other troubleshooting procedures.
When this switch is off, switch position 2 selects which of two diagnostic modes is available. The
burn-in mode (switch 8 off and switch 2 off) is used with special test equipment at the Milnor
factory to test the controller board, but is not suitable when the controller board is installed in a
machine.
PELLERIN MILNOR CORPORATION
Switch Position 4
Setting
Off
On
Off
On
— End of BICEUC01 —
—In some locations the temperature of
—Switch positions 4 and 5
Switch Position 5
Setting
Off
Off
On
On
—The available
—Switch position 7 determines whether the
—Switch position 8