Terminate Button; Last Rinse Light; Formula A Button; Formula B Button - Milnor MWR09E5 Series General Operating And Troubleshooting

Washer-extractors with the e-p onetouch controller
Hide thumbs Also See for MWR09E5 Series:
Table of Contents

Advertisement

Chapter 3. Operating

Formula C button (

3.2.2.1.
3.
mode (DIP switch position 8 is on), this button cycles the display through its four modes: DIP
switch settings, timer display, inputs display, and outputs display. Each display is fully described
in Section 4.1. "Troubleshooting Errors".
In testing mode, holding the Formula C button depressed makes input C to the microprocessor.
Display or Action
ABCDEFGH
--+-----

Formula D button (

3.2.2.1.
4.
and a formula is running. In testing mode, holding the Formula D button depressed makes input
D to the microprocessor.
Display or Action
ABCDEFGH
---+----

Terminate Button

3.2.2.2.
progress. All controls are immediately locked out for a safety delay of 75 seconds.
In testing mode, the Terminate button provides input F to the microprocessor.

Last Rinse Light

3.2.2.3.
the beginning of the last bath step (last rinse) until the formula ends, 75 seconds after the end of
the final extract step.
In testing mode, the Last Rinse light illuminates when output 8 is on.

In Progress Light

3.2.2.4.
when output j is present.
Display or Action
abcdefghijklmnop
--+--+---+------
In testing mode, the In Progress light illuminates when output 9 is on.

Door Unlock Button

3.2.2.5.
75 seconds after a formula ends for any reason. The door cannot be unlocked until the 75-second
safety delay expires. The safety delay also applies for 75 seconds after power is first applied to
the machine.
In testing mode, the Door Unlock button is energized only when output 00 is on. With output 00
on, you should hear the door unlock when this button is pressed.
PELLERIN MILNOR CORPORATION
)
—With the display kit attached and the machine in normal operation
>
Explanation
Typical display in testing mode with button
Output #
00 is On
)
—This button is ignored if the machine is in normal operation mode
?
Explanation
Typical display in testing mode with button
Output #
00 is On
—In normal operation mode, this button terminates the formula in
—During normal operation the Last Rinse light illuminates constantly from
—In normal operation with the display attached, this light is illuminated
Explanation
Typical display during normal operation with the drain closed
(output c), the basket turning clockwise (output f), and the In
Progress light illuminated (output j).
—In normal operation with the display attached, this button is enabled
— End of BICEUF01 —
held depressed.
>
held depressed.
?

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mwr18e4

Table of Contents