Paradyne COMSPHERE 3920Plus Technical Reference Manual page 320

Comsphere 392 plus series
Hide thumbs Also See for COMSPHERE 3920Plus:
Table of Contents

Advertisement

COMSPHERE 392xPlus Modems
Digital Bridging
Figure G-8 shows a sample for Digital Bridging.
19200(TMp)
FEP
1
2
3
4
Cable 1
1
2
3
Cable 3
4
1
2
3
4
1
3920Plus A
3920Plus
B, C
3910Plus D
G-16
Cntrl
Cable 2
A
3920Plus
Backup
Dial
B
3920Plus
Cable 4
Backup
Dial
C
3920Plus
Cable 4
*
Backup
Dial
D
3910
Cable 4
*
Could be 3920Plus or 3910
Figure G-8. Sample Configuration  Digital Bridge
Use TMp Control Template default configuration options with the following
exception:
MUX Mode
Use Sync Dial template default configuration options with the following
exceptions:
MUX Mode
NetworkPosition
Diag Connection
Tx Clock Source
LSD Control
DTR Action
Use Sync Dial template default configuration options with the following
exceptions:
NetworkPosition
Diag Connection
Tx Clock Source
LSD Control
14400(TMp)
Cable 2
3920Plus
Cable 4
Cable 2
3920Plus
Cable 4
Cable 2
3920Plus
Cable 4
Set to DTE Bridge.
Set to DTE Bridge.
Set to Control.
Set to NMS(CC).
Set to Port 1.
Set to Sim_Cntl_Car.
Set to Ignore.
Set to Control.
Set to NMS(CC).
Set to External.
Set to Sim_Cntl_Car.
October 1998
Cable 1
DTE
Addr = 1
(Sync)
1
2
E
DTE
Addr = 2
3
(Sync)
4
DTE
Addr = 3
(Sync)
1
2
F
Cable 1
3
4
DTE
Addr= 4
(Sync)
1
2
G
DTE
Addr = 5
3
(Sync)
4
Cable 1
495-14612a-01
3920-A2-GH30-40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3921plus

Table of Contents