Paradyne COMSPHERE 3920Plus Technical Reference Manual page 252

Comsphere 392 plus series
Hide thumbs Also See for COMSPHERE 3920Plus:
Table of Contents

Advertisement

COMSPHERE 392xPlus Modems
S-Register
S28
Port4 Ext Alarm. Register determines whether Port 4 is used to pass user data
or to monitor for external alarms.
Register has the following values:
0 = Disable
1 = EnableLow
4 = EnableHigh
The factory setting is Disable.
S30
Sync DTE Rate. Register determines the modem's synchronous DTE rate
(transmit clock/receive clock frequency). This register is effective when the
modems are connected in a synchronous data compression or synchronous
buffer mode and when the applicable configuration option (TX Clk Source or
Bakup_TXClk_Src) is set to Internal.
Register has the following values:
0 = 115,200
1 = 76,800
2 = 57,600
3 = 38,400
4 = 28,800
5 = 19,200
6 = 14,400
7 =
8 =
9 =
10 =
11 = 128,000
12 = 112,000
13 = 96,000
14 = 72,000
15 = 64,000
16 = 56,000
17 = 48,000
The factory setting is 128,000.
S31
DTE Alarm Mask. Register enables the reporting of DTE alarms (in Singleport
mode) to the front panel and/or NMS.
Register has the following values:
0 = Disable
1 = Enable
The factory setting is Disable.
S32
2 Sec LSD Hold. LSD is held on for a maximum of 2 seconds.
Register has the following values:
0 = Disable
1 = Enable
The factory setting is Disable.
14-20
Table 14-3
(4 of 15)
392xPlus S-Registers
Description
9,600
4,800
2,400
1,200
October 1998
DCP LCD
Command
Sequence
Configure\Edit\
DTE
Interface\MUX
Configure\Edit\
DTE Interface
Configure\Edit\
Line Dialer
Configure\Edit\
Leased_Line
3920-A2-GH30-40