Select the appropriate port by pressing the corresponding F key. Press the
ports into view.
The Pick Test Port screen does not appear in Singleport mode.
The message Started appears on the LCD and the Test LED lights.
The port field (for example, P1 for Port 1) displays the port that is currently selected. You may
see P1, P2, P3, or P4.
BlksErrd=xxxxxxx displays the number of blocks of data found in error (block size is 1000 bits
per block). BlksRcvd=xxxxxxx displays the total number of blocks of data received. Select
Clear to reset both block counters. In Singleport mode the message NoSync can appear as a
value for BlksErrd while the modem's receiver is synchronizing. The message OvrFlw can
appear as the value for BlksErrd if the counter overflows.
Press the
Press the
The Pattern test can be exited and reentered without restarting the test. The BlksErrd and
BlksRcvd continue counting.
If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of
the test. If it is disabled, the test operates until aborted. For more information on the Test
Timeout configuration option, refer to the Test section in Chapter 5, Configure Branch.
To exit this function and remain in the Test branch, press the
Top-Level menu, press the
8-10
Test:P1:Pattern
Started
F1
F2
F3
Test P1:Pattern
>
BlksErrd=xxxxxxx
F3
F1
F2
key to display BlksRcvd=xxxxxxx, number of blocks of data received.
key to display Clear. Select Clear to reset the block counters.
key.
October 1998
key to scroll other
key. To exit and return to the
3920-A2-GH30-40