displays and press any function key. Primary channel operation is not available when
initiating a Remote function from a TMp tributary modem.
If the remote modem accepts the password and the entry is successful, the Top-Level menu of
the remote modem appears on the local modem's LCD. An
corner indicating that what is displayed on your LCD is actually the Top-Level menu of the
remote 392xPlus modem. If the message Remote FP Busy appears, the remote modem's front
panel is already in Remote mode.
Status
Configure
The Top-Level menu of the remote 392xPlus modem is similar to the local 392xPlus modem
with the following exceptions:
• The Talk/Data and Security branches do not appear.
• Change Directory is the only function available under the Call Setup branch.
• Local Analog Loop and Remote Digital Loop do not appear under the Test branch when
• Poll List Display is the only function available under the PList branch.
• Exit Remote replaces Remote on the local modem's LCD.
To return to local modem operation, select ExitRem. Any changes made to configuration options
in the remote modem are saved.
The following conditions can cause Remote branch access to fail:
• The local modem is not able to communicate with the remote modem because of a poor
• If a connection is established but the remote modem's Access from Remote configuration
• If a connection is established but the wrong password is stored, the status message
• The remote mode command displays Other Test Active if an Analog Loopback test is
13-4
Leased:33.6
Control
ExitRem
F1
F2
PList
Control
using the secondary channel. When using the primary channel, the Test branch does not
appear.
dial network or leased-line connection, or the remote modem is not a 3900 Series modem.
If this is the case, the status message No Response appears on the LCD.
option is disabled, then the status message Access Disabled appears on the LCD.
Password Invalid appears on the LCD. This configuration option must be enabled by the
remote user. (Refer to the Remote Access Password configuration option in Chapter 5,
Configure
Branch.)
currently running.