VF Thresholds Update
The VF Thresholds Update function allows you to set the thresholds that determine the Health
and Status alarm conditions for the VF parameters. Refer to
thresholds and their valid ranges and default values.
To access VF_Thresh_Update from the Control branch, make the following selections:
Press the
VF_Thresh_Update.
Select Edit.
In the following example, the RSL High threshold is changed from 09 (– dBm) to 10. This
example demonstrates VF threshold editing and saving. With the exception of Signal Quality, all
VF thresholds may be modified in this manner. Signal Quality uses a menu selection with
possible values of Excelent (Excellent), Good, Fair, Poor, or No Signal. Editing and saving a VF
threshold is similar to editing and saving a configuration option. (For another example of editing
and saving, refer to the
Configure Branch.)
In the example shown above, 09 is the upper (High) RSL threshold (in – dBm). To change the
09 to 10, make the following selections:
Select the F2 ( " ) key to increment the number above the cursor ( 0 ) to 1.
3920-A2-GH30-40
Control:
<
VF_Thresh_Update
F3
F1
F2
key until VF_Thresh_Update appears. Press any function key to select
VF Thresholds
Edit
Save
Reset
F1
F2
F3
Editing and Saving a Configuration Option
RSL High (- dBm)
" 09
Nxt
F3
F1
F2
RSL High (- dBm)
" 19
Nxt
r
F1
F2
F3
October 1998
Control Branch
Table 7-1
in this section for VF
section in Chapter 5,
7-17