Pin Assignment For The Power Connector; Pin Assignment For The Flash Trigger Receptacle - Basler WOOD BURNING FIREPLACE Wood Burning Fireplace

Table of Contents

Advertisement

2.1.3 Pin Assignment for the Power Connector

The power input connector type is a microminiature push-pull lock type connector, the Hirose
HR 10A-7R-6PB. The power supply should deliver 12 V at a minimum of 500 mA (A504
450 mA (A503
plug is given in Table 2-3.
Pin
Number
1, 2
3, 4
5, 6
Table 2-3:A500
You can use the Hirose HR 10A-7P-6S connector for your cable.

2.1.4 Pin Assignment for the Flash Trigger Receptacle

The Flash trigger output connector type is a microminiature push-pull lock type connector, the
Hirose HR 10A-7R-4S. The receptacle provides a signal (FlashOut) for an external flash. This
signal can be programmed via the FlashCtrl register. The signal can be deactivated, or tied to an
"effective exposure" signal (Integrate Enabled) generated internally, or tied to the external ExFlash
input, or it can be permanently active. The effective exposure is the period when charges are
actually accumulated by the sensor.
The output signal can selected to be TTL Active High (default setting), Low Side Switch (Open
Collector), or High Side Switch via the Flash Trigger Modes register (see section 4.2.4.16).
The pin assignment is given in Table 2-4. Figure 2-4 shows the three variants of output schematics
of the flash trigger connector.
Pin
Number
2
1, 3
4
Table 2-4:A500
You can use the Hirose HR 10A-7P-4P connector for your cable.
The FlashOut signal is short-circuit proof. The signal is electrically isolated from other signals in
the camera. See the timing diagram in Figure 2-3 and the flash trigger output schematics in Figure
2-4.
Basler A500
k
PRELIMINARY
) or 250 mA (A501
) with a voltage accuracy of ±10%. The pin assignment of the
k
k/kc
Signal
Direction
Name
+12 VDC
Input
not connected
DC GND
Input
Pin Assignment for the Power Receptacle
k
Signal
Direction
Name
FlashOut
Output
not connected
DC GND
Output
Pin Assignment for the Flash Trigger Receptacle
k
Level
Function
12 VDC ± 10%
DC power
Ground
DC ground
Level
Function
Signal
Flash trigger; the HIGH signal is current limited
to 50 mA ±20%.
Ground
DC ground
Camera Interface
),
k/kc
2-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A500kA503kA504kA504kcA501kA501kc

Table of Contents