Troubleshooting; Led - Basler WOOD BURNING FIREPLACE Wood Burning Fireplace

Table of Contents

Advertisement

6 Troubleshooting

Fault finding using the camera LED is described in section 6.1.

6.1 LED

cameras regularly perform self tests. Detected errors are signaled by flashes of the LED
A500
k
on the back of the camera. The number of flashes indicates the detected error. If several error
states are present, the LED outputs the error codes in succession.
See Table 6-1 for the description of the flashes and the error states.
LED
Orange and on
Continuous
3 flashes
5 flashes
6 flashes
7 flashes
8 flashes
Table 6-1: Camera Status Indicators
Basler A500
k
PRELIMINARY
Description
The camera has power and is OK.
ExSync has not changed state for 5 seconds or longer. If you are not supplying
an ExSync signal to the camera, this is a normal condition and should be ignored.
Otherwise check the cable and the ExSync generating device.
The Work Set could not be stored into a User set.
Contact Basler support.
A User Set or the Factory Set could not be loaded into the Work Set.
Contact Basler support.
A valid list of commands was not available.
Contact Basler support.
The FPGA could not be configured. Contact Basler Support