Test Image Command - Basler WOOD BURNING FIREPLACE Wood Burning Fireplace

Table of Contents

Advertisement

4.2.5 Test Image Command

Purpose:
To enable or disable a test image, and to select a test image. See section
explanation of the available test images.
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
Basler A500
k
PRELIMINARY
Cmd-ID
R/W-Flag
0xA1
1
Cmd-ID
R/W-Flag
0xA1
0
Cmd-ID
R/W-Flag
0xA1
0
None
Byte 1
An ID that specifies the test image (see the table below).
ID
Test Image
0x00
Image from sensor (standard mode)
0x01
Gray Gradient Test Image
0x02
Color Gradient Test Image (Bayer pattern)
0x03
Running Line Test Image
0x04
White Screen Test Image
Configuring the Camera
Data Length
Data
1
Data Length
Data
1
1 Byte
Data Length
Data
1
1 Byte
for an
3.12
-
4-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A500kA503kA504kA504kcA501kA501kc

Table of Contents