Read Microcontroller Firmware Version; Read Fpga Firmware Version; Read Temperature - Basler WOOD BURNING FIREPLACE Wood Burning Fireplace

Table of Contents

Advertisement

Configuring the Camera

4.2.6.7 Read Microcontroller Firmware Version

Purpose:
To read the microcontroller firmware version.
Type:
This is a read only command.
Read Command:
Response:
Data Format:

4.2.6.8 Read FPGA Firmware Version

Purpose:
To read the FPGA firmware version.
Type:
This is a read only command.
Read Command:
Response:
Data Format:

4.2.6.9 Read Temperature

Purpose:
To read the camera's temperature. The temperature is measured on the inner PCB.
Type:
This is a read only command.
Read Command:
Response:
Data Format:
4-26
PRELIMINARY
Cmd-ID
R/W-Flag
0x40
1
Cmd-ID
R/W-Flag
0x40
0
Byte 1
Low byte of firmware version
Byte 2
High byte of firmware version
Byte 3
Register Layout ID
Cmd-ID
R/W-Flag
0x41
1
Cmd-ID
R/W-Flag
0x41
0
Byte 1
Low byte of firmware version
Byte 2
High byte of firmware version
Byte 3
Register Layout ID
Cmd-ID
R/W-Flag
0x70
1
Cmd-ID
R/W-Flag
0x70
0
The result is given in °C as 8 bit signed number.
Data Length
Data
3
Data Length
Data
3
3 Bytes
BCD coded
BCD coded
Data Length
Data
3
Data Length
Data
3
3 Bytes
BCD coded
BCD coded
Data Length
Data
1
Data Length
Data
1
1 Byte
-
-
-
Basler A500
k

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A500kA503kA504kA504kcA501kA501kc

Table of Contents