Exsync, Edge-Controlled Mode - Basler WOOD BURNING FIREPLACE Wood Burning Fireplace

Table of Contents

Advertisement

Basic Operation and Features

3.3.1 ExSync, Edge-controlled Mode

When using the ExSync edge-controlled mode to control exposure, several guidelines must be
followed:
• ExSync must remain high for a minimum of 1 µs.
• ExSync must remain low for a minimum of 1 µs.
• When using full resolution, the minimum ExSync period is 2 ms for the A504
for the A503
• If the AOI feature is used, the minimum ExSync signal period is equal to
1/Maximum Frame Rate where the maximum frame rate is determined by the suitable for-
mula in section 3.11.1.
Assuming that these general guidelines are followed, the reaction of the camera to a rising ExSync
signal will be one of three cases, which are described in sections 3.3.1.1,
The FlashOut signal can be set into a mode where it is high while the effective ex-
posure occurs, i.e. while the Integrate Enabled signal is high.
3-10
PRELIMINARY
and 13.52 ms for the A501
k
.
k/kc
, 2.485 ms
k/kc
3.3.1.2
and 3.3.1.3.
Basler A500
k

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A500kA503kA504kA504kcA501kA501kc

Table of Contents