Configuring the Camera

4.2.2.4 Write Command

In the normal case, when a write command is sent to the camera, the camera responds with an
ACK.
If the camera receives a write command with an unknown command ID in the descriptor, it will
respond with an ACK but will not perform the write.
After a write command has been issued by the host, the host can verify the write by issuing a
corresponding read command and checking that the returned data is as expected. The host can
also issue a camera status read command (see section 4.2.8) and check the returned data to see
if an error condition has been detected.
For many of the write commands listed in the Tables on pages 5-4-11 through 5-4-
31, only data within a specified range or a specified group of values is valid. The
camera does not perform a check to see if the data in the write command is within
the allowed range or specified group of allowed values.