4.2.9 Bitrate Command

Purpose:
To set the bitrate of the serial communications link. The bitrate is changed immediately after
the successful receipt of this command. (The default bitrate is 9600.)
Type:
This is a write only command.
Write Command:
Response:
Data Format:
When changing the bitrate for serial communication, use the following procedure:
Basler A500
k
PRELIMINARY
Cmd-ID
0x44
None
Byte 1
Byte 2
Byte 3
Byte 4
ID
Bitrate
0x12
4800
0x13
9600
0x14
14400
0x15
19200
0x17
38400
0x19
57600
0x1A
76800
0x1B
115200
1. Issue the write command with the new bitrate.
2. Wait one second.
3. Change the bitrate on the serial port that the camera is using:
a) If you are using a Camera Link frame grabber, change the bit rate on the
frame grabber's RS-644 serial port.
b) If you are using the camera with a k-BIC, change the bit rate on your PC's
RS-232 serial port (A501
4. Resume communication.
Notes: At a camera reset or a power off/on, the camera will return to the 9600 bps
default setting.
The RS-644 serial port on some Camera Link frame grabbers will only support a
bitrate of 9600. If you are using a Camera Link frame grabber, check the grabber's
documentation before attempting to change the bitrate.
R/W-Flag
Data Length
0
4
An ID that specifies the bitrate (see table below).
undefined - always write 0x00
undefined - always write 0x00
undefined - always write 0x00
only).