2 Camera Interface

2.1 Connections

2.1.1 General Description

area scan cameras are interfaced to external circuitry via
A500
k
• a 26 pin, 0.5" Mini D Ribbon (MDR) connector to transmit configuration, trigger and image
data via Camera Link,
• a microminiature push-pull lock type receptacle to provide power (12 V) to the camera,
• a microminiature push-pull lock type receptacle to provide a signal for an external flash.
A504
and A503
k/kc
• a second 26 pin, 0.5" Mini D Ribbon (MDR) connector to transmit further image data via
Camera Link.
• a 15 pin HDSub receptacle for the VGA monitor output (A504
The connectors are located on the back of the camera. Figure 2-1 shows the plugs and the status
LED which indicates signal integrity and power OK.
Basler A500
k
PRELIMINARY
area scan cameras have additional connectors:
k
Camera Interface
only)
k/kc
2-1