2.1.2 Pin Assignment for the MDR 26 Camera Link Connector(s)

The pin assignment for the MDR 26 pin connector used to interface video data, control signals,
and configuration data is given in Table 2-1. Table 2-2 provides the pin assignment for the second
MDR 26 pin connector which is only available with the A504
Camera Link Connector 1:
Pin
Number
1, 13, 14,
1
26
15
2
16
3
17
4
19
6
18
5
7
20
21
8
22
9
10
23
24
11
12
25
1
Pins 1, 13, 14, and 26 are all tied together to GND inside of the camera.
Table 2-1: A500
Basler A500
k
PRELIMINARY
Signal
Direction
Name
Gnd
Input
X0+
Output
X0-
X1+
Output
X1-
X2+
Output
X2-
X3+
Output
X3-
XClk+
Output
XClk-
SerTC+
Input
SerTC-
SerTFG+
Output
SerTFG-
CC1+
Input
CC1-
CC2+
Input
CC2-
CC3+
Input
CC3-
CC4+
Input
CC4-
Pin Assignments for the First MDR 26 Pin Connector
k
k/kc
Level
Function
Ground
Ground for the inner shield of the cable
Channel Link
Data from Channel Link transmitter
LVDS
Channel Link
Data from Channel Link transmitter
LVDS
Channel Link
Data from Channel Link transmitter
LVDS
Channel Link
Data from Channel Link transmitter
LVDS
Channel Link
Transmit clock from Channel Link transmitter
LVDS
RS-644
RS-644 Serial communication data receive,
LVDS
channel RxD input
RS-644
RS-644 Serial communication data transmit,
LVDS
channel TxD output
RS-644
ExSync: External trigger
LVDS
RS-644
ExClk. The input is not supported.
LVDS
RS-644
ExFlash: External Flash Trigger
LVDS
RS-644
Not used
LVDS
Camera Interface