Vertical Pole Mount - Extreme Networks Altitude 4760 Series Installation Manual

Table of Contents

Advertisement

Altitude 4760 Series Access Point Hardware Mounting and Installation

Vertical Pole Mount

Use the following procedures for vertical pole mount installations. Use of the extension arm
is recommended when mounting the Access Point to poles greater than 3 inches is diameter.
For Poles Up To 3 Inches In Diameter When Using A U-bolt:
1 Thread the two inner nuts onto the U-bolt. Place the U-bolt at the desired mounting
location.
2 Place the pole mount bracket section on the U bolt. Adjust the inner nuts until the pole
mount bracket section is against the pole and the U-bolt can be secured tightly to the
pole.
3 Place the angle adapter bracket section on the U-bolt with the open slot connections on
the bottom and align it with the pole mount section.
4 Put the two outer nuts on the U-bolt to attach the angle adapter bracket section to the
pole mount bracket section.
5 Tighten all nuts to 300 inch pounds (lbf-in).
6 Position the Access Point bracket section so that the bottom of the section with the
straight (not bevel cut) sides is oriented toward the bottom side of the AP with the gore
vent. Using a torque wrench, or a ratchet and a 10mm socket, or an adjustable wrench,
attach (but don't tighten) the Access Point bracket section to the Altitude 4760 Series
Access Point with the four M6 hex flange screws.
7 Insert two M6 hex flange screws into the bottom holes on the sides of the Access Point
bracket section.
Altitude™ 4760 Series Access Point Installation Guide
30

Advertisement

Table of Contents
loading

Table of Contents