Hardware Installation Guidelines
Hardware Installation Guidelines
CAUTION
All device wiring must comply with the National Electric Code (NEC) or regulations and
procedures defined by the regulatory bodies of the country or region where the devices are being
deployed. All local building and structure codes must be observed.
WARNING!
Strictly observe the following safety warnings and precautions when installing an Altitude
4760 Series Access Point.
Precautions
Before installing an Altitude 4760 Series Access Point verify the following grounding and
lightning protection notes:
The installation professional should be familiar with all grounding requirements and
●
regional codes and ensure that the Access Point and mounting asset are properly
grounded. The grounding cable for an Altitude 4760 Series Access Point must be at a
minimum a #10 gauge wire cross section. The cable can be attached to the unit using one
of the following methods:
Loosen the grounding screw, insert the grounding cable into the hole below it, and
●
tighten the screw.
Loosen the grounding screw, wind the grounding cable around it, and tighten the
●
screw.
Attach a ring lug to the grounding cable and secure it to the unit using the grounding
●
screw.
To properly attach the grounding cable to the Access Point, refer to
●
Access Point Grounding Screw" on page
For Ethernet and lightning protection, it is recommended that a commercially available
●
off-the-shelf Lightning Protection Unit (LPU) be used on all shielded CAT5E Ethernet
connections. The LPU should be rated for outdoor use.
Altitude™ 4760 Series Access Point Installation Guide
21.
"Altitude 4760 Series