Brother DCP-8110DN Service Manual page 78

Laser mfc
Hide thumbs Also See for DCP-8110DN:
Table of Contents

Advertisement

Error code 1E00
Replace Parts
Drum
The number of rotations of the drum unit is reaching the life limit.
Step
Replace the drum unit with a
new one and reset the drum
1
counter. If the error display is
not cleared, the main PCB is
faulty.
Error codes 1F00 to 2300
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Error code 2400
Print Unable 24
Turn the power off and then back on again.
An error occurred in the internal temperature thermistor.
Step
Connection failure of the
1
internal temperature thermistor
harness
Internal temperature thermistor
2
failure
3
Main PCB failure
Error codes 2500 to 3500
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Cause
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
Cause
Reconnect the internal temperature thermistor
harness.
Replace the Internal temperature thermistor.
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
2-33
Remedy
Remedy
Remedy
Remedy
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents