Brother DCP-8110DN Service Manual page 107

Laser mfc
Hide thumbs Also See for DCP-8110DN:
Table of Contents

Advertisement

Error code CA00
Unusable Device
Remove the Device. Turn the power off and back on again.
A USB device not within the specifications is connected to the USB terminal, resulting in
overcurrent.
<User Check>
• Remove the USB device that is not within the specifications.
Step
1
Main PCB failure
Error codes CB00 to CF00
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Error code D000
---
An error occurred while initializing the touch panel.
Step
Connection failure of the touch
1
panel PCB harness
2
Touch panel PCB failure
3
Main PCB failure
Error code D100
Print Unable D1
See Troubleshooting and routine maintenance chapter in User's Guide.
An error occurred while initializing the modem.
Step
1
Main PCB failure
Error codes D200 to DC00
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Cause
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
Cause
Reconnect the touch panel PCB harness.
Replace the touch panel PCB ASSY.
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
2-62
Remedy
Remedy
Remedy
Remedy
Remedy
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents