Magnum Energy ME-RC Owner's Manual page 18

Standard remote control
Hide thumbs Also See for ME-RC:
Table of Contents

Advertisement

3.0 Setup
FEATURES/SETTINGS
Main
Menu
Menu
Heading/Item
01
Search
Search=
Watts
02 Low
Batt
CutOut
03
Absorb
Absorb Hrs=
Time
04 Bat-
BatType=
tery Type
05
Charge
Max Charge=
Rate
06 VAC
Dropout=
Dropout
11
Selections/
Adjustments Range
OFF, 5 - 50W
LBCO=
9.0 - 12.2 VDC*
0.1 - 25.5 Hrs
Gel, Flooded, AGM1, AGM2
Absorb =
(12.0 - 16.0V)*
Cus-
Float =
tom
(12.0 - 16.0V)*
[2]
Equalize =
(12.0 - 16.0V)*
Max Amps =
(OFF, 20 - 990A)
Chg Volts =
(12.0 - 16.0V)*
EndChg = (Time,
DC Amps, Hold
VDC)
EndChg = Time
DoneTime =
(0.1 - 25.5 Hrs)
MaxTime =
CC/
(OFF, 0.1-25.5)
CV
Recharge =
(12.0-16.0V)*
EndChg= DC Amps
DoneAmps =
(0 - 250ADC)
MaxTime =
(OFF, 0.1-25.5)
Recharge =
(12.0-16.0V)*
Hold VDC
0 - 100%
10 - 100%
US Models: 60 - 100
VAC, UPS Mode
Export Models: 110 - 190
VAC, UPS Mode
©2013 Magnum Energy, Inc.
Model/
Default
Level
Setting
Required
Level 1
5W
Level 1
10.0 VDC
Level 4
1.5 Hrs
[4]
Level 1
Flooded
14.4V
Level 3
13.2V
15.6V
200A
13.8V
Level 3
Time
1.5Hrs
Level 4
12.0Hrs
[4]
12.0V
20ADC
Level 4
12.0Hrs
12.0V
Level 1
14.6V
Level 3
80%
Level 2
Level 1
80 VAC
Level 1
150 VAC