Using A Me-Ags-N Module; Me-Ags-N Setup; Table 7-1, Me-Rc Autostart/Autostop Matrix; Figure 7-1, Me-Rc's Ags Configuration Access Buttons - Magnum Energy ME-RC Owner's Manual

Standard remote control
Hide thumbs Also See for ME-RC:
Table of Contents

Advertisement

7.0

Using a ME-AGS-N Module

The ME-RC remote's AGS menus under the AGS and TECH buttons allow
you to customize and monitor the operating parameters for your autostart/
autostop generator system. To help confi gure and operate the AGS with your
ME-RC, refer to the mini index below to direct you to the appropriate section.

7.1 ME-AGS-N Setup

7.2 ME-AGS-N Functional Tests
7.3 ME-AGS-N Operation/Monitoring
7.4 Enabling the ME-AGS-N
7.5 Starting and Stopping the Generator
7.6 ME-AGS-N Menu Map
Figure 7-1, ME-RC's AGS Confi guration Access Buttons
7.1
ME-AGS-N Setup
Press the AGS button on ME-RC remote (Figure 7-1), and then rotate
the SELECT knob to navigate to the AGS menus. These menus allow the
generator to be automatically started and stopped based on different
parameters. Using Table 7-1, determine the specifi c autostart and autostop
condition with which you want the generator to be automatically controlled,
and then use that specifi c menu setting to confi gure the AGS.
Note: For information on using the AGS: 01 AGS Control, AGS: 02 AGS
Status, and AGS: 08 AGS TECH menus, refer to Section 7.3 "AGS Operation/
Monitoring".

Table 7-1, ME-RC Autostart/Autostop Matrix

Autostart
Condition
Gen starts on high
temperature, or
Gen starts on low
inverter battery
voltage
©2013 Magnum Energy, Inc.
7.0 Using an AGS Module: Setting Up
DC 12.6V
5A
SHORE
AGS METER SETUP TECH
AGS and TECH Buttons
See AGS Menu
04 Start Temp F
Gen stops after a
(page 59)
set time period, or
05 Start Volts
Gen stops at Quiet
(page 60)
Time
page 58
page 62
page 62
page 65
page 65
page 66
Autostop
See AGS Menu
Condition
03 Run Time Hour
(page 59)
07 Quiet Time
(page 61)
58