General problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 7, "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530," on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
Trained service technician.
v Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom
A cover lock is broken, an LED
is not working, or a similar
problem has occurred.

Hard disk drive problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 7, "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530," on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
Trained service technician.
v Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom
Not all drives are recognized by
the hard disk drive diagnostic
test (the Fixed Disk Test).
The server stops responding
during the hard disk drive
diagnostic test.
A hard disk drive was not
detected while the operating
system was being started.
A hard disk drive passes the
diagnostic Fixed Disk Test or
SCSI Attached Disk Test, but
the problem remains.
Action
If the part is a CRU, replace it. If the part is a FRU, the part must be replaced by a
trained service technician.
Action
Remove the drive that is indicated by the diagnostic tests; then, run the hard disk
drive diagnostic test again. If the remaining drives are recognized, replace the
drive that you removed with a new one.
Remove the hard disk drive that was being tested when the server stopped
responding, and run the diagnostic test again. If the hard disk drive diagnostic
test runs successfully, replace the drive that you removed with a new one.
Reseat all hard disk drives and cables; then, run the hard disk drive diagnostic
tests again.
Run the diagnostic SCSI Attached Disk Test (see "Running the diagnostic
programs" on page 67).
Note: This test is supported on server models with RAID arrays that use the
ServeRAID-BR10il, ServeRAID-MR10i, or ServeRAID-MR10is controllers or servers
with SATA hard disk drives that use the onboard SATA/SAS controller to create
RAID arrays. Use the Fixed Disk Test for SATA hard disk drives or servers that
have RAID arrays.