Lenovo ThinkServer TS200 6522 Hardware Maintenance Manual page 101

Table of Contents

Advertisement

Table 5. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 7, "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530," on page 201 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained service
technician.
v Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new
device drivers or to submit a request for information.
Message
number
Component
201-810-xxx
Memory
201-901-xxx
Memory
Test
State
Memory Test
Aborted
Memory Test
Failed
Description
Action
Test stopped:
1. Turn off and restart the system.
unknown error
2. Run the test again.
code xxx received
3. Make sure that the DSA code is at the
in COMMONEXIT
latest level. For the latest level of
procedure.
DSA code, go to http://
www.lenovo.com/support.
4. Make sure that the server firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see "Updating the
firmware" on page 258.
5. Run the test again.
6. If the failure remains, go to the
Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
Test failure:
1. Turn off the system and disconnect
single-bit error,
it from the power source.
failing DIMM z.
2. Reseat DIMM z.
3. Reconnect the system to power and
turn on the system.
4. Make sure that the DSA code is at
the latest level. For the latest level of
DSA code, go to
http://www.lenovo.com/support.
5. Make sure that the server firmware
is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see "Updating the
firmware" on page 258.
6. Run the test again.
7. Replace the failing DIMMs.
8. Re-enable all memory in the Setup
utility (see "Using the Setup Utility"
on page 246).
9. Run the test again.
10. Replace the failing DIMM.
11. If the failure remains, go to the
Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
93
Chapter 4. Diagnostics

Advertisement

Table of Contents
loading

Table of Contents