Table 5. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 7, "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530," on page 201 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained service
technician.
v Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new
device drivers or to submit a request for information.
Message
number
Component
201-805-xxx
Memory
201-806-xxx
Memory
201-807-xxx
Memory
Test
State
Memory Test
Aborted
Memory Test
Aborted
Memory Test
Aborted
Description
Action
Test canceled: the
1. Turn off and restart the system.
memory controller
2. Run the test again.
display/alter write
3. Make sure that the server firmware is
operation was not
at the latest level. The installed
completed.
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see "Updating the
firmware" on page 258.
4. Run the test again.
5. If the failure remains, go to the
Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
Test canceled: the
1. Turn off and restart the system.
memory controller
2. Run the test again.
fast scrub operation
3. Make sure that the server firmware is
was not completed.
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see "Updating the
firmware" on page 258.
4. Run the test again.
5. If the failure remains, go to the
Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
Test canceled: the
1. Turn off and restart the system.
memory controller
2. Run the test again.
buffer free request
3. Make sure that the server firmware is
failed.
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see "Updating the
firmware" on page 258.
4. Run the test again.
5. If the failure remains, go to the
Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
91
Chapter 4. Diagnostics