v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v SeeChapter 7, "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530," on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
A PCI SERR has occurred on
system %1.
(%1 = CIM_ComputerSystem.
ElementName)
Fault in slot System board on
system %1.
(%1 = CIM_ComputerSystem.
ElementName)
Error
A PCI SERR has occurred.
(Sensor = One of PCI Err)
Error
1. Check the extender-card
LEDs.
2. Reseat the affected adapters
and extender card.
3. Update the server and adapter
firmware (UEFI and IMM).
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
4. Remove both adapters.
5. Replace the PCIe adapter.
6. Replace the extender card.
7. (Trained service technician
only) Replace the system
board.
1. Check the extender-card
LEDs.
2. Reseat the affected adapters
and extender card.
3. Update the server and adapter
firmware (UEFI and IMM).
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
4. Remove both adapters.
5. Replace the PCIe adapter.
6. Replace the extender card.
7. (Trained service technician
only) Replace the system
board.