Recovering The Server Firmware - Lenovo ThinkServer TS200 6522 Hardware Maintenance Manual

Table of Contents

Advertisement

Table 5. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 7, "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530," on page 201 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained service
technician.
v Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new
device drivers or to submit a request for information.
Message
number
Component
405-908-xxx
Intel Ethernet
Device

Recovering the server firmware

Important: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
If the server firmware has become corrupted, such as from a power failure during an update, you can
recover the server firmware in one of two ways:
v In-band method: Recover server firmware, using either the boot block jumper (Automated Boot
Recovery) and a server Firmware Update Package Service Pack.
v Out-of-band method: Use the IMM Web Interface to update the firmware, using the latest server
firmware update package.
Note: You can obtain a server update package from one of the following sources:
v Download the server firmware update from the World Wide Web.
v Contact your Lenovo service representative.
To download the server firmware update package from the World Wide Web, go to http://
www.lenovo.com/support.
The flash memory of the server consists of a primary bank and a backup bank. It is essential that you
maintain the backup bank with a bootable firmware image. If the primary bank becomes corrupted, you
can either manually boot the backup bank with the boot block jumper, or in the case of image corruption,
this will occur automatically with the Automated Boot Recovery function.
Test
State
Test LEDs
Failed
Description
Action
1. Make sure that the component
firmware is at the latest level. The
installed firmware level is shown in
the DSA event log in the
Firmware/VPD section for this
component. For more information, see
"Updating the firmware" on page
258.
2. Run the test again.
3. Replace the component that is
causing the error. If the error is
caused by an adapter, replace the
adapter. Check the PCI Information
and Network Settings information in
the DSA event log to determine the
physical location of the failing
component.
4. If the failure remains, go to the
Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
105
Chapter 4. Diagnostics