v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v SeeChapter 7, "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530," on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
The System %1 encountered a POST
Error.
(%1 = CIM_ComputerSystem.
ElementName)
A Uncorrectable Bus Error has
occurred on system %1.
(%1 = CIM_ComputerSystem.
ElementName)
34
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual
Error
A POST error has occurred.
(Sensor = Firmware Error)
Error
A bus uncorrectable error
has occurred.
(Sensor = Critical Int PCI)
1. Update the server firmware
on the primary page.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
2. (Trained service technician
only) Replace the system
board.
1. Check the system-event log.
2. Check the PCI error LEDs.
3. Remove the adapter from the
indicated PCI slot.
4. Check for a server firmware
update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
5. (Trained service technician
only) Replace the system
board.

Advertisement

Table of Contents
loading

Table of Contents