Diagnostic Text Messages; Viewing The Test Log; Diagnostic Messages - Lenovo ThinkServer TS200 6522 Hardware Maintenance Manual

Table of Contents

Advertisement

Note: After you exit from the stand-alone memory diagnostic environment, you must restart the
server to access the stand-alone memory diagnostic environment again.
5. Select gui to display the graphical user interface, or select cmd to display the DSA interactive menu.
6. Follow the instructions on the screen to select the diagnostic test to run.
If the diagnostic programs do not detect any hardware errors but the problem remains during normal
server operations, a software error might be the cause. If you suspect a software problem, see the
information that comes with your software.
A single problem might cause more than one error message. When this happens, correct the cause of the
first error message. The other error messages usually will not occur the next time you run the diagnostic
programs.
Exception: If multiple error codes or LEDs indicate a microprocessor error, the error might be in a
microprocessor or in a microprocessor socket. See "Microprocessor problems" on page 55 for information
about diagnosing microprocessor problems.
If the server stops during testing and you cannot continue, restart the server and try to run the diagnostic
programs again. If the problem remains, replace the component that was being tested when the server
stopped.
For a list of diagnostic messages, see Chapter 4, "Diagnostics," on page 17.

Diagnostic text messages

Diagnostic text messages are displayed while the tests are running. A diagnostic text message contains
one of the following results:
Passed: The test was completed without any errors.
Failed: The test detected an error.
Aborted: The test could not proceed because of the server configuration.

Viewing the test log

To view the test log when the tests are completed, type the view command in the DSA interactive menu,
or select Diagnostic Event Log in the graphical user interface. To transfer DSA Preboot collections to an
external USB device, type the copy command in the DSA interactive menu.

Diagnostic messages

The following table describes the messages that the diagnostic programs might generate and suggested
actions to correct the detected problems. Follow the suggested actions in the order in which they are
listed in the action column.
68
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Hardware Maintenance Manual