Lenovo ThinkServer TS200 6522 Hardware Maintenance Manual page 45

Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v SeeChapter 7, "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530," on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Array %1 is in critical condition.
(%1 = CIM_ComputerSystem.
ElementName)
Array %1 has failed.
(%1 = CIM_ComputerSystem.
ElementName)
Memory uncorrectable error
detected for DIMM All DIMMs on
Memory Subsystem All DIMMs.
Memory Logging Limit Reached for
DIMM All DIMMs on Memory
Subsystem All DIMMs.
Memory DIMM Configuration Error
for All DIMMs on Memory
Subsystem All DIMMs.
Memory uncorrectable error
detected for DIMM One of the
DIMMs on Memory Subsystem One
of the DIMMs.
Error
An array is in Critical state.
(Sensor = Drive n Status)
(n = hard disk drive number)
Error
An array is in Failed state.
(Sensor = Drive n Status)
(n = hard disk drive number)
Error
A memory uncorrectable
error has occurred.
Error
The memory logging limit
has been reached.
Error
A DIMM configuration error
has occurred.
Error
A memory uncorrectable
error has occurred.
Replace the hard disk drive that
is indicated by a lit status LED.
Replace the hard disk drive that
is indicated by a lit status LED.
1. If the server failed the POST
memory test, reseat the
DIMMs.
2. Replace any DIMM that is
indicated by a lit error LED.
Note: You do not have to
replace DIMMs by pairs.
3. Run the Setup utility to enable
all the DIMMs.
4. Run the DSA memory test.
1. Update the server firmware to
the latest level.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
2. Reseat the DIMMs and run
the DSA memory test.
3. Replace any DIMM that is
indicated by a lit error LED.
Make sure that DIMMs are
installed in the correct sequence
and have the same size, type,
speed, and technology.
1. If the server failed the POST
memory test, reseat the
DIMMs.
2. Replace any DIMM that is
indicated by a lit error LED.
Note: You do not have to
replace DIMMs by pairs.
3. Run the Setup utility to enable
all the DIMMs.
4. Run the DSA memory test.
Chapter 4. Diagnostics
37

Advertisement

Table of Contents
loading