v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v SeeChapter 7, "Parts listing, TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530," on page 201 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Sensor CPU nOverTemp has
transitioned to non-recoverable.
(n = microprocessor number)
A bus timeout has occurred on
system %1.
(%1 = CIM_ComputerSystem.
ElementName)
The System %1 encountered a POST
Error.
(%1 = CIM_ComputerSystem.
ElementName)
Error
A sensor has changed to
Nonrecoverable state.
Error
A bus timeout has occurred.
Error
A POST error has occurred.
(Sensor = ABR Status)
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow,
that the air baffle is in place
and correctly installed, and
that the server cover is
installed and completely
closed.
2. Make sure that the heat sink
for microprocessor n is
installed correctly.
3. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
1. Remove the adapter from the
PCI slot that is indicated by a
lit LED.
2. Replace the extender card.
3. Remove all PCI adapters.
4. (Trained service technicians
only) Replace the system
board.
1. Recover the server firmware
from the backup page (see
"Recovering the server
firmware" on page 105).
2. Update the server firmware to
the latest level.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.