8. If you are installing a full-length adapter, remove the blue adapter guide (if any) from the end of the
adapter.
1
Adapter guide
9. Carefully grasp the adapter by the top edge or upper corners, and align it with the expansion slot
guides; then, press the adapter firmly into the expansion slot. Move the adapter directly from the
static-protective package to the expansion slot.
Attention: Make sure that the adapter is correctly seated in the expansion slot before you turn on
the server. Incomplete installation of an adapter might damage the system board or the adapter.
10. Install an expansion-slot screw at the rear of the adapter.
11. If you are installing a full-length adapter, press on the release lever on the right side of the front
adapter-retention bracket to release the retaining tab on the left side of the bracket.
12. Connect required cables to the adapter. Route cables so that they do not block the flow of air from
the fans.
13. Reinstall the rear adapter-retention bracket; then, rotate the bracket to the closed position.
Note: If any adapters in the server are large or have heavy cables attached to them, you can remove
the rear adapter-retention bracket and secure all of the adapters with expansion-slot screws.
14. Go to "Completing the FRU replacement" on page 190.

Replacing the ServeRAID-BR10il v2 SAS/SATA controller

Use the following procedures to replace the ServeRAID-BR10il v2 SAS/SATA controller.

Removing a ServeRAID BR10-il controller

To remove the mini-SAS/SATA RAID controller, complete the following steps:
1. Read the safety information that begins on page 1.
2. Turn off the server and all attached devices; then, disconnect all power cords and external cables.
Note: When you disconnect the power source from the server, you lose the ability to view the LEDs
because the LEDs are not lit when the power source is removed. Before you disconnect the power
source, make a note of which LEDs are lit, including the LEDs that are lit on the operation
information panel and LEDs inside the server on the system board.
3. Unlock and remove the side cover (see "Removing the side cover" on page 130).
4. Open the rear adapter-retention bracket until the release lever on the right side of the bracket clicks
into place.