- Specific characteristics in MAX/MIN mode in THD (from 10Hz to 1kHz):
4.3

ENVIRONMENTAL CONDITIONS

Conditions
Temperature
Relative humidity (RH)
4.4

MECHANICAL SPECIFICATIONS

Housing
Jaws
Screen
Dimension
Weight
4.5

POWER SUPPLY

Batteries
Battery Life
Auto Power Off
Accuracy: add 1% R to the values in the tables above.
Capture time of the extreme: approximately 100ms
-4° to +131°F
(-20° to +55°C)
≤90% up to 131°F (55°C)
Rigid polycarbonate shell with over-molded elastomer
covering;
UL94 V1
Polycarbonate
Opening: 1.9" (48mm)
Clamping diameter: 1.9" (48mm)
LCD display unit
Blue backlighting
Dimension: 1.6 x 1.9" (41 x 48mm)
10.7 x 3.6 x 1.6" (272 x 92 x 41mm)
1.32 lbs (600g) with the batteries
4x1.5V AA LR6
>350 hours (without backlighting and Bluetooth)
After 10 minutes with no switch and/or button activity
Operating
77
Storage
-40° to +158°F
(-40° to +70°C)
≤90% up to 158°F (70°C)