AEMC 5233 User Manual

AEMC 5233 User Manual

Digital multimeter with non-contact detection

Advertisement

Quick Links

5233
DIGITAL MULTIMETER
with Non-Contact Detection
E N G L I S H
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for AEMC 5233

  • Page 1 5233 DIGITAL MULTIMETER  with Non-Contact Detection E N G L I S H User Manual...
  • Page 2 The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com. Serial #: ________________________________ Catalog #: 2125.65 Model #:...
  • Page 3: Table Of Contents

    3.8 Continuity Test ................13 3.9 Diode Test ................14 3.10 Capacitance Test ..............15 3.11 Temperature Test ..............16 3.12 Current Measurement .............17 4. MAINTENANCE ................18 4.1 Warning ..................18 4.2 Battery Replacement ..............18 4.3 Fuse Replacement ..............19 4.4 Cleaning ..................19 Digital Multimeter Model 5233...
  • Page 4 5. SPECIFICATIONS................20 Repair and Calibration ................23 Technical and Sales Assistance ............23 Limited Warranty ...................24 Warranty Repairs ...................24 Digital Multimeter Model 5233...
  • Page 5: Introduction

    “equivalents”. Repairs and adjustments must be done by approved qualified personnel. • Replace the battery as soon as the symbol appears on the display unit. Disconnect all leads before opening the battery compartment cover. • Use personal protective equipment when conditions require. • Keep your hands away from unused terminals of the instrument. • When handling probes or contact tips, keep your fingers behind the guards. Digital Multimeter Model 5233...
  • Page 6: International Electrical Symbols

    CAT II: For measurements performed on circuits directly connected to the electrical distribution system. Examples are measurements on household appliances or portable tools. CAT III: For measurements performed in the building installation at the distri- bution level such as on hardwired equipment in fixed installation and circuit breakers. CAT IV: For measurements performed at the primary electrical supply (<1000V) such as on primary overcurrent protection devices, ripple control units, or meters. Digital Multimeter Model 5233...
  • Page 7: Receiving Your Shipment

    Save the damaged packing container to substantiate your claim. Ordering Information Multimeter Model 5233 ............Cat. #2125.65 Includes set of two 5 ft color-coded leads (red/black) with needle tip {1000V CAT IV 15A), thermocouple Type K with adapter, set of three fuses 10A, 600V, 50kA, (fast blow) 5x32mm, soft carrying case and a user manual.
  • Page 8: Product Features

    • AC voltmeter with low input impedance (voltage measurements for electricity and electrical engineering) • AC/DC voltmeter with high input impedance (voltage measurements for electronics) • Frequency and duty cycle measurements • Ohmmeter • Continuity test with buzzer • Diode test • Ammeter • Capacitance meter • Thermometer in °C or °F by measurement and linearization of the voltage across the terminals of a K-type thermocouple Digital Multimeter Model 5233...
  • Page 9: Control Features

    2. Analog and digital display (see § 2.3) 3. Function buttons (see § 2.4) 4. Rotary switch (see § 2.5) 5. Current measurement 10A terminal (see § 3.12) 6. Positive (Red) input and COM (Black) input Digital Multimeter Model 5233...
  • Page 10: Display Features

    Voltage Hertz Duty Cycle Farad °C Degrees Celsius °F Degrees Fahrenheit Ampere Prefix “nano” µ Prefix “micro” Prefix “milli” Prefix “kilo” Prefix “Mega” Continuity Beeper Enabled Diode Test Low Battery Auto Power OFF function activated Digital Multimeter Model 5233...
  • Page 11: Button Functions

    AC or DC voltage measurement (mV) Resistance measurement; Continuity test; Diode test µF Capacitance measurement °C/°F Temperature measurement AC or DC current measurement NCV (Non-contact Voltage) + Partial OFF mode of the multimeter (NCV function active) Digital Multimeter Model 5233...
  • Page 12: Operation

    A long press on the button during start-up, while turning the switch to any range, deactivates the Auto-OFF function. The symbol is not displayed. Auto and Manual Range Selection By default, the meter is in auto-range. This is indicated by the AUTO symbol on the display. While on, the instrument will automatically adjust to the correct measurement range when taking the measurement. To change the range selection to Manual, press the button. Digital Multimeter Model 5233...
  • Page 13: Non-Contact Voltage (Ncv)

    Non-Contact Voltage (NCV) • Turn the rotary switch to the NCV position. • Move the Model 5233 (NCV detection sensor) close to the potentially live conductor(s) (presence of phase). If a network voltage of 90V is present, the back-lighting lights up red, oth- erwise, it remains off. Voltage Measurement The Model 5233 measures AC voltage at low input impedance (V Z), DC and AC voltages.
  • Page 14: Resistance Measurement

    • Turn the rotary switch to the range. • Insert the red lead to the red “+” input jack and the black lead to the black “COM” input jack. • Connect the test probe tips to the sample under test. Figure 3-2 Digital Multimeter Model 5233...
  • Page 15: Continuity Test

    • Insert the red lead to the red “+” input jack and the black lead to the black “COM” input jack. • Connect the test probe tips to the sample under test. • The buzzer sounds when the circuit to be checked is DC or has a resistance of less than 100Ω ± 3Ω. Figure 3-3 Digital Multimeter Model 5233...
  • Page 16: Diode Test

    • Insert the red lead to the red “+” input jack and the black lead to the black “COM” input jack. • Connect the test probe tips to the sample under test. Figure 3-4 Digital Multimeter Model 5233...
  • Page 17: 3.10 Capacitance Test

    • Turn the rotary switch to the position. • Insert the red lead to the red “+” input jack and the black lead to the black “COM” input jack. • Connect the test probe tips to the sample under test. Figure 3-5 Digital Multimeter Model 5233...
  • Page 18: 3.11 Temperature Test

    (ºC/ ºF) • Connect the temperature probe adapter to the “COM” and “+” terminals, observing the polarity. • Connect the temperature probe to the adapter, observing the polarity. NOTE: If the probe is disconnected or open-circuit, the display unit indicates Figure 3-6 Digital Multimeter Model 5233...
  • Page 19: 3.12 Current Measurement

    AC or DC. • Insert the red lead to the “10A” input jack and the black lead to the “COM” input jack. • Connect the multimeter in series in the circuit. Figure 3-7 Digital Multimeter Model 5233...
  • Page 20: Maintenance

    The batteries will need to be replaced when the symbol appears on the display. • The meter must be in the OFF position and disconnected from any circuit or input. • Using a screwdriver, unscrew the four screws of the battery compartment cover on the back of the housing. • Replace the old battery with one new 9V battery, observing the polarity. • Replace the battery compartment cover and tighten the screws. Digital Multimeter Model 5233...
  • Page 21: Fuse Replacement

    • To clean the instrument, wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Dry thoroughly before use. • Do not get water inside the case. This may lead to electrical shock or damage to the instrument. Digital Multimeter Model 5233...
  • Page 22: Specifications

    * According to safety rules, 1000V range is limited to 600V. **NOTE: A low input impedance serves to eliminate the effects of interference voltages due to the supply network and makes it possible to measure AC voltage with minimum error. Digital Multimeter Model 5233...
  • Page 23 Fast blow fuse F10A/600V/50kA, 6.3x32 Accuracy (±) 1.5% + 3cts AC Current (10A 10A* Resolution 0.001A 0.01A Protection Fast blow fuse F10A/600V/50kA, 6.3x32 Accuracy (±) 40Hz to 1kHz; 2% + 3cts * 15A for a maximum of 60 seconds. Digital Multimeter Model 5233...
  • Page 24 IEC/EN 61010-1, 1000V CAT III, 600V CAT IV; Pollution Degree 2 Double Insulated Electro-magnetic EN-61326/A2:2001 Compatibility Drop Test 1m (in accordance with standard IEC-68-2-32) Case Protection IP54 as per EN 60529 Specifications are subject to change without notice Digital Multimeter Model 5233...
  • Page 25: Repair And Calibration

    NOTE: You must obtain a CSA# before returning any instrument. Technical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your instrument, please call, mail, fax or e-mail our technical support team: AEMC Instruments ® 200 Foxborough Boulevard Foxborough, MA 02035 USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 techsupport@aemc.com www.aemc.com NOTE: Do not ship Instruments to our Foxborough, MA address. Digital Multimeter Model 5233...
  • Page 26: Limited Warranty

    , not by the distributor from whom it was purchased. This ® warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC ® For full and detailed warranty coverage, go to www.aemc.com. The war- ranty information is located in our customer service section. What AEMC will do: ® If a malfunction occurs within the one-year period, you may return the instrument to us for repair, provided you submit a proof of purchase. AEMC...
  • Page 28 02/14 99-MAN 100359 v3 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 15 Faraday Drive • Dover, NH 03820 USA • Phone: (603) 749-6434 • Fax: (603) 742-2346 www.aemc.com...