  • Page 1 Clamp-On Multimeters Models 701 and 703 USER MANUAL Chauvin Arnoux, Inc. d.b.a. AEMC Instruments ® 99-MAN-100071 Rev 03 01/98...
  • Page 2 Clamp-On Multimeters Models 701 and 703 USER MANUAL Ω Ω Ω Ω AEMC Model 701 AEMC Model 703 CLAMP-ON METER I N S T R U M E N T S I N S T R U M E N T S TRMS CLAMP-ON METER _ –...
  • Page 3 Owner’s Record The serial number for the Clamp-On Multimeters Models 701 or 703 is located inside the battery compartment of your instrument. Please record this number and purchase date for your records. CLAMP-ON MULTIMETER MODEL 701 CATALOG #1207.51 SERIAL #:...
  • Page 4: Table Of Contents

    Specifications ......... 4 Controls, Model 701 ........10 Controls, Model 703 .
  • Page 5: Warning

    600 Vrms. • Never make resistance measurements on a live circuit. • Never make diode tests on a live circuit. • Do not have voltage or current inputs connected at the same time. Clamp-on Multimeters Models 701 & 703...
  • Page 6: International Electrical Symbols

    International Electrical Symbols This symbol signifies that the Models 701 and 703 are protect- ed throughout by double or reinforced insulation. Only use specified replacement parts when servicing the meter. This symbol signifies CAUTION! and requests that the user refer to the user manual before using the meter.
  • Page 7: Description

    9 V battery and a user manual. We designed and built the Models 701 and 703 for reliability: the right size; the right functions, display and performance; the right single-hand- ed operation; the right professional tool.
  • Page 8 1. Additional error with CF 2. Additional error with CF CF from 1.5 to 2.5: 5% R CF from 1.5 to 3: 3% R CF from 2.5 to 5: 8% R CF from 3 to 5: 8% R Clamp-on Multimeters Models 701 & 703...
  • Page 9 1.2 mA Range 400 to 4 kΩ 400 to 4 kΩ Resolution 1Ω 1Ω Basic Accuracy ± 1% R ± 1% R Open Voltage 4.4 V 4.4 V Short Circuit Current 1.2 mA 1.2 mA Clamp-on Multimeters Models 701 & 703...
  • Page 10 0 to 4 V 0 to 4 V Resolution 0.001 V 0.001 V Open Voltage 4.4 V 4.4 V Short Circuit Current 1.2 mA 1.2 mA Additional Functions Max Display Hold Max Display Hold Clamp-on Multimeters Models 701 & 703...
  • Page 11: General Specifications

    Battery: 9 V alkaline battery; automatic low battery indicator Life: Model 701: 180 hr typical Model 703: 100 hr typical Typical consumption: Model 701: 2.5 mA without buzzer Model 703: 3.5 mA without buzzer Buzzer: Continuous beep for the continuity sound test below 20Ω Frequency: 2.5 kHz Dimensions: 10 x 3.8 x 1.7”...
  • Page 12 Dielectric Test: 6 kV between terminals and case Overload Protection: Voltage: 1000 Vrms Current: 700 Arms(@ 500 Hz @ 50°C) Ohms: 600 Vrms Continuity/Diode: 600 Vrms Frequency: see voltage and current Warranty: One year Clamp-on Multimeters Models 701 & 703...
  • Page 13: Controls, Model 701

    5. MAX The MAX button displays the maximum value of the signal measured. 6. Rotary Selector Switch 6-position rotary switch selects the main functions for Model 701. 7. Display Digital 4000-count Measurement function and control function symbols 8. Jacks...
  • Page 14 Model 701 Ω Ω AEMC Model 701 CLAMP-ON METER I N S T R U M E N T S _ – HOLD Ω Clamp-on Multimeters Models 701 & 703...
  • Page 15: Controls, Model 703

    Measurement function and control function symbols 8. Jacks Two input terminals for the measurement of DC and AC voltages, resistance, continuity, diode tests and frequency COM : black : red 9. Lever/Trigger Trigger opens and closes the clamp jaws. Clamp-on Multimeters Models 701 & 703...
  • Page 16 Model 703 Ω Ω AEMC Model 703 I N S T R U M E N T S TRMS CLAMP-ON METER HOLD Clamp-on Multimeters Models 701 & 703...
  • Page 17: Digital Display Features

    Displayed when measuring resistance Displayed when performing the diode test For the Model 703 only: Displayed when performing a RMS measurement Displayed when performing a frequency measurement Displayed when performing the continuity with sound test HOLD Clamp-on Multimeters Models 701 & 703...
  • Page 18: Ac Current Measurements

    1 A to 700.0 A. 4. If you have the instrument positioned so that you cannot read the display, press the HOLD button on the side of the instrument to freeze the reading. Remove the clamp-on and read. Clamp-on Multimeters Models 701 & 703...
  • Page 19: Ac And Dc Voltage Measurements

    COM jack. Select the appropriate termination (test probes or clips). 3. Touch or connect the voltage test leads to the circuit under test. 4. Take the reading from the display. Voltage measurements are pos- sible from 0.0 to 600 V. Clamp-on Multimeters Models 701 & 703...
  • Page 20: Max Value Measurements

    1. Turn the switch to the Ω function. 2. Connect the red lead to the + terminal and black to the terminal. 3. Take the reading from the display. Resistance measurements are possible from 0 to 4 kΩ. Clamp-on Multimeters Models 701 & 703...
  • Page 21: Continuity Sound Test

    2. Connect the red lead to the terminal and the black lead to the COM terminal. 3. If the resistance is less than 40Ω, the buzzer emits a continuous beep and displays the value of the resistance. Clamp-on Multimeters Models 701 & 703...
  • Page 22: Diode Tests

    Frequency measurement on the current input: 1. Check that the test leads of the Model 703 are disconnected. 2. Set the switch to the Hz function. 3. Clamp the jaws around the conductor and take the reading. Clamp-on Multimeters Models 701 & 703...
  • Page 23: Maintenance

    Keep the jaws perfectly clean so that they close correctly. The faces should be cleaned with a lightly oiled soft cloth. To clean the Model 701 or 703 wipe the case and jaw covers with a damp cloth and mild detergent. Do not use any abrasives or solvents.
  • Page 24 Battery Replacement WARNING: Never disassemble the instrument without first disconnecting it from all external electrical sources. Clamp-On Multimeter Models 701 and 703 are powered by a 9-volt battery. The battery replacement indicator will display continuously when battery replacement is required.
  • Page 25: Repair And Calibration

    Repair and Calibration To guarantee that your instrument complies with the factory specifica- tions, we recommend that the Models 701 & 703 be submitted to our factory service center at one-year intervals for recalibration, or as required by other standards.
  • Page 26: Technical And Sales Assistance

    CHAUVIN ARNOUX, Inc. d.b.a. AEMC ® Instruments 200 Foxborough Blvd. Foxborough, MA 02035 USA Tel: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 www.aemc.com Clamp-on Multimeters Models 701 & 703...
  • Page 27 NOTES Clamp-on Multimeters Models 701 & 703...
  • Page 28: Limited Warranty

    What You Must Do: First obtain a return authorization by phone or by fax from AEMC ® Instruments, then return the Clamp-on Multimeters Models 701 & 703, indicating place and date of purchase, with a written explana- tion of the reason for return. Return material, postage pre-paid to: Chauvin Arnoux, Inc. d.b.a. AEMC ®...

This manual is also suitable for:

703