3.11 ENERGY METERING MEASUREMENT

The Energy Metering measurement is available in W for the AC and AC+DC
quantities.
The energy meters start and totalize the various types of energy (the eight
energy meters - 4 meters of energy consumed and 4 meters of energy generated
- are started).
To measure the energy metering, proceed as follows:
1.
Set the switch to
2.
Press the
mode appears. The display reads "Counting Off".
3.
Connect the black lead to the COM terminal and the red lead to the "+"
terminals.
4.
Place the test probes or the alligator clips of the black lead on the
neutral (N), then those of the red lead on the L phase.
5.
Clamp around only the corresponding conductor, respecting the
direction of current flow (see §3.10).
6.
To start the metering, press the
"Counting On".
The metering sequence is as follows:
I-
--->
--->
I<-------------------------------------|
.
(long press). Start-up screen 1 in the Energy Metering
--->I
35
(yellow) button. The display reads